Home Community MRI MRI/MRS combo can improve early detection of breast cancer

MRI/MRS combo can improve early detection of breast cancer

Communities
MRI is so sensitive that it reveals even non-cancerous suspicious growths in the breasts. But any suspect lesions can be imaged with MRS, with no need for an invasive biopsy. The American Cancer Society recently issued new recommendations for women with a higher risk of developing breast cancer, including those with a family history of breast or ovarian cancer, and those who may carry genetic mutations (BRCA1 or BRCA2) that make them more likely to develop the disease. Specifically, it recommends the use of screening MRI as an alternative to conventional mammography for women at higher risk, because the former is more sensitive and can detect hidden tumors that might otherwise escape notice.

However, according to UNLV's Dr. Phillip Patton, the lead investigator on the project, MRI is so sensitive that it reveals even non-cancerous suspicious growths in the breasts, providing insufficient specifics about whether such growths are malignant. This in turn leads to many unnecessary biopsies and additional scans, not to mention heightened anxiety. In this new approach, any suspect lesions can be imaged with MRS, with no need for an invasive biopsy. Spectroscopy can be used to test for any number of chemical compounds. In breast MRS, it is useful in measuring the amount of a metabolite called choline in suspect lesions. In most cases, elevated levels of choline are a strong indicator of malignancy (cancer).

Thus far, the UNLV researchers have done MR spectroscopy on healthy patients without breast cancer as proof of principle. As expected, choline levels were low. The next step is to image patients with breast cancer to confirm that MRS can be used to detect the telltale higher choline levels. The UNLV study is being conducted in conjunction with Spring Valley Nevada Imaging Centers Amigenics and Philips Medical Systems. The study is the first step in what Patton and colleagues hopes will be a series of clinical studies on the efficacy of MRS to distinguish between normal and cancerous tissue, including comparisons to other magnetic field strengths for both MRI and MRS.

Patton and graduate student Rob Etnire are using a 3.0 T MR spectrometer, the highest magnetic strength allowable for clinical use by the FDA. There have been prior similar published studies, but those used 1.5 T or 4.0 T spectrometers; Patton’s team is the first to publish results using the 3.0 T instrument. "In theory, the higher magnetic strength gives more signal to noise for the same imaging time," explains Etnire "Thus, it will either improve the quality of the image, or shorten the time to obtain a certain quality image."

Neither MRI nor MRS uses the ionizing radiation (X-rays) that is used in traditional mammography and CT breast scans, and both procedures can be completed in a single sitting. Nor does adding MRS elevate the cost of the procedures substantially. There are already concerns about the higher cost of MRI compared to conventional mammography - breast MRI costs between $1,000 and $2,000, ten times that of a mammogram -- particularly in light of the million or more women who are likely to undergo breast MRI each year as a result of the new ACS guidelines. For those at higher risk, however, the extra cost is
worthwhile.

UNLV's combined MRI/MRS technique will not be widely available clinically for several years. But Patton and Etnire are hopeful that as the public becomes more aware of the advantages to be gained from breast MRI, it will become a more widely used clinical technique for breast cancer detection, paving the way for the newer concept of coupling MRI with MRS.

While there are clear benefits to combining MRI and MRS, Srirama Swaminathan, a senior clinical scientist with Philips Medical Systems, cautions that there are still some limitations. For instance, not all breast cancers demonstrate elevated choline levels, and at least one form of breast cancer shows no choline signal at all. Nor will MRS detect very small lesions. "In spite of the added value MRS brings to improving specificity in characterizing lesions, it is not the 'magic bullet' for improving specificity across all types of lesions," he said.


Source: Health Physics Society

Reprinted by permission of Newswise
http://www.newswise.com/articles/view/531374/
Trackback(0)
Comments (0)Add Comment

Write comment
smaller | bigger

busy
 

Related Articles

MRI Products

MRI Companies

MRI Join Group

Description: This group is for professionals involved in the MRI sector. Keep up-to-date with news, informed discussion and network with thought leaders.
Created: August 25, 2009, 8:54 pm
Owner: Devisree

Latest News

March 20, 2010, 12:02 pm By Deepa iCAD: Prostate & Breast MRI Imaging Technologies iCAD Takes Leadership Position in Meeting the Need for Accredited Educational Initiatives on Prostat...
March 19, 2010, 8:48 am By Deepa Medtronic Announces Advisa DR MRI SureScan Pacemaker Medtronic, Inc. announced the commercial availability of the Advisa DR MRI™ SureScan™ pacemaker in s...
March 17, 2010, 11:37 am By Deepa MRI-guided Ablation for Prostate Cancer Recurrences In prostate cancer patients following radical prostatectomy, magnetic resonance-guided ablation usin...
March 17, 2010, 8:59 am By Deepa STRMC Highlights Advantages of New MRI South Texas Regional Medical Center (STRMC) has announced that patients and physicians in the commun...
March 16, 2010, 11:54 am By Deepa MRI to Decide Heart Transplantation, LVAD Therapy AGH doctors tout potential of MRI as predictor of which heart failure patients will benefit most fro...
Discussions in MRI

Paul Keough
November 2, 2009, 1:44 pm ASTRO Sun Nov 1st: Integrating New and Emerging Modalities into Radiation Therapy Daivd Kirsh, MD, PhD, gave an excellent presentation, comment on your thoughts on these topics he ra...

Paul Keough
October 22, 2009, 12:47 pm buzz arounf er MRI? What are you seeing as patients, doctors, providers as far as testimonials around the use of er MRI?...
Comments in MRI
No Comments added yet.
Members
View all